Whether you want lighting to pick out particular corners of the garden or power for a summer house, jacuzzi or workshop, we bring together the good looks and the practical side and build it to last outdoors.
Regulated Work, Not A Trailing Lead
Garden electrics and lighting fall under Part P and must meet the 18th Edition of the wiring regulations, so every outdoor project we take on is designed, tested and certified to the same standard as the work indoors. That is not red tape for its own sake, it is what keeps a wet, cold environment safe.
The failures we get called to fix are always the same: indoor cable pressed into outdoor duty, joints wrapped in tape and buried in a border, fittings whose weather rating was never checked. The proper answer is armoured cable, weatherproof accessories and RCD protection on everything past the wall.
Aesthetics And Function, Built For Weather
Summer Houses, Offices And Hot Tubs
Jobs run from a single weatherproof socket for the mower to a fully wired garden office or a hot tub supply, in gardens from Caerleon through to Bassaleg. Each gets the cable, the fittings and the protection specified for that site and that load, along with an honest steer on what the garden genuinely needs rather than what pads out an invoice.
The Factors We Design Around
Because Part P governs all of it, every installation is built around a few non-negotiable factors. Only equipment and accessories designed for outdoor use go in, chosen to suit the garden's exposure to weather. RCD protection covers every outdoor socket and circuit, cutting the supply in a fraction of a second if a fault develops. And cable is routed and buried to the correct depth, or clipped and protected where a buried run does not suit.
Get those right and the first proper storm of autumn changes nothing about how the garden's electrics behave.
A Building Deserves Its Own Circuit
A garden office with heating, a computer and a kettle is a small building, not an extension-lead problem. It gets an armoured supply from the house, its own compact consumer unit, and enough capacity that a fan heater in January does not black out a video call.
Hot tubs are the same conversation with wetter stakes, so they get a dedicated supply, an outdoor-rated rotary isolator within reach, and RCD protection without exception. The retailer's manual tells us the rating, and that tells us the circuit.
Outdoor Electrics Questions
You can, and each winter it grows a little more dangerous. A permanent armoured supply costs less than people expect and takes the daily gamble away. If the shed holds anything beyond a mower on charge, it has earned the proper job.
Deep enough that a spade will not find it, typically around half a metre with warning tape laid above, though the route and surface matter. Clipped runs along walls and fences skip the digging where the layout allows, and we choose whichever suits your garden.
Yes. RCD protection is required, and the socket itself has to be a weatherproof type rated for external use with its cover intact. An ordinary indoor socket pressed into outdoor service is exactly what an EICR flags, so it is worth doing right first time.
Yes, it is one of our regular jobs. The tub's rating decides the circuit, and the install includes a dedicated supply, an isolator you can reach and RCD protection. The manual gives us everything we need to quote it accurately.