Installation, Testing & Servicing

Emergency Lighting Newport

As a business owner you are required to meet the current standards for emergency lighting, which means keeping escape routes and exits properly lit when a power cut takes the normal lighting away.

Caerleon Rogerstone Bettws Malpas Langstone Risca Cwmbran View Areas Covered →
Emergency Lighting Newport

Emergency Lighting In Newport

Installation, Maintenance And Testing

Alongside installation we handle the maintenance and routine testing of emergency lighting, at intervals that suit the building type, and we are glad to talk through what your particular premises needs. When the mains fails, emergency luminaires run on their own batteries and light the way out: the escape routes, the exits, the stairs and the points where fire equipment sits.

BS 5266 sets out where the light has to fall and for how long, which is why a compliant system is designed rather than dotted about. We install new systems, extend and repair existing ones, and take on the testing where the logbook has gone quiet.

Coverage For When The Lights Go Out

  • New system design and installation
  • Escape route and open area coverage
  • Exit signage, maintained and non-maintained
  • Monthly function and annual duration testing
  • Battery and luminaire replacement
  • Logbooks brought up to date
  • Communal areas for blocks and HMOs
  • Combined visits with fire alarm servicing

Does Your Business Need Emergency Lighting?

See All Areas We Cover →

Buildings That Need It, Citywide

Venues, Blocks, Offices And Stairwells

The systems we look after sit in hospitality venues around the city centre, communal stairwells in converted blocks and flats above shops, and offices and units across Spytty, Queensway Meadows and the wider business parks. HMO and flat landlords are a frequent surprise audience: communal escape routes need emergency lighting, and plenty of owners learn that from a licensing letter rather than a light going out.

We Never Switch Off24 Hours A Day
Call Our Newport Team01633 226033

Assured ElectriciansOur Accreditations

  • NICEIC Registered
  • Part P Compliant
  • BS 7671 18th Edition
  • Safecontractor Member
  • MCS Accredited
  • RECC Member
  • CHAS Member
  • OZEV Approved Charge Point Installer
  • Trustmark Member
  • Fully Insured

Coverage In Every Area

Stairwells To Corridors And Beyond

If the regulations feel like a maze, that is exactly where we come in. Our consultations give you clear guidance on meeting the legal requirements and, above all, keeping staff safe, and years of installing emergency lighting across every kind of space, from stairwells and corridors to restrooms and back-of-house areas, means the coverage we design leaves no dark corner on the escape route.

A walk round the building against the standard usually turns up two or three spots the original system missed, and we list them plainly and price closing them as one job.

The Testing Regime

Monthly Check, Annual Endurance

The standard routine is a brief monthly function test proving every luminaire switches to battery, and an annual full-duration test proving the batteries last their rated period, usually three hours. Both go in the logbook, because an untested system is legally no different from a broken one.

We run the regime for clients who would rather not own another recurring chore, dealing with batteries and failures as we find them and keeping the records ready for inspection.

Frequently Asked Questions

Emergency Lighting Questions

Does my small business really need it?

If people could need to escape in darkness, your fire risk assessment will almost certainly say yes, and that assessment is what the law holds you to. Layout matters more than size: a small unit with one obvious lit exit needs less than a warren of corridors, and a survey tells you which you have.

Maintained or non-maintained fittings, what is the difference?

Maintained fittings stay lit all the time and remain lit on battery when the power fails, standard for exit signs in occupied venues. Non-maintained fittings stay dark until the supply drops, common on escape routes. Most buildings mix the two, decided by the design.

Who can test emergency lighting?

A competent person. The monthly function test is simple enough for trained on-site staff, while the annual duration test is best done professionally, since failures at full discharge need proper diagnosis. Many clients do the months and hand us the annuals.

Our system fails its tests. Repair or replace?

Usually batteries and individual luminaires first, since those are the consumables. A system failing across the board, or built to a standard several revisions old, sometimes warrants replacement, and we give you the honest arithmetic for both.